Process Conditions

DUNGS HeatEngine® based on high level engineering and global legal specifications.
To select your best fitting solution we defined following application and process requirements.

Requirements and Process Conditions

Requirements
Process chamber pressure​
Process temperature​
Ambient temperature
Gas inlet pressure
Process air flow velocity
Burner installation position
Fuel
Emissions @ 17 % O2
min.
-5 mbar (-2 "W.C.)
20 °C (70 °F)
-15 °C (5 °F)
30 mbar (0,5 psig)
2 m/s (6,5 ft/s)
all(vertical, horizontal, upside-down)
• Natural gas H or L• LPG, Propane (Butane < 5 %)• Biogas (on request)• Hydrogen (on request)
• NOx < 10 ppm over entire turndown range• CO < 13 ppm over entire turndown range (< 5 ppm on increased low capacity and depending on specific installation)
max.
+3 mbar (+1 "W.C.)
450 °C (840 °F)
60 °C (140 °F)
65 mbar (1 psig)
5 m/s (16 ft/s)

Main Features: 

  • Low emissions and high turndown 

  • Homogeneous flame profile leads to low NOx combustion 

  • Quiet operation and compact burner flame 

  • Different burner geometries 

  • High power density allows controlled heat input and compact design 

  • Optimised fan with speed-regulated EC motor

  • Robust system: easy to handle, low maintenance requirements and easy cleaning 

Our application engineers are looking forward to supporting you!

Contact us

Karl Dungs GmbH & Co. KG

Karl-Dungs-Platz 1
73660 Urbach, Germany